0

Your Cart

Your cart is empty
Asset No: 9059
Category: TOILET & ABLUTION BLOCKS

6m x 3m Male & Female Toilet Block – Sewer Connect (9059)

This new 6.0m x 3.0m male and female toilet block is configured for sewer connection and provides separate amenity areas, stainless-steel basins and a wall-mounted stainless-steel urinal. Insulated panel construction, wet-area vinyl flooring and purpose-built fittings provide a practical transportable amenities solution.

or
SKU: 9059 Category: Brand: ,

<!– wp:acf/product-tab {"name":"acf/product-tab","data":{"product_tab_title":"Overview","_product_tab_title":"field_6820ef6263371","product_tab_image":"","_product_tab_image":"field_6820ef62633aa","product_tab_content":"

6m x 3m Male & Female Sewer-Connect Toilet Block

Asset 9059 is a new 6.0m x 3.0m transportable male and female toilet block configured for sewer connection. The issued floor plan provides separate male and female amenity areas, with stainless-steel basin facilities, toilet cubicles and a wall-mounted stainless-steel urinal.

The building uses insulated panel construction with Surfmist external wall and roof finishes, Basalt external corner and roof flashings, and a 3° roof pitch. Wet areas are finished with commercial-grade grey slip-resistant vinyl, coved 100mm up the walls.

Technical specifications

  • Overall footprint: 6.0m x 3.0m.
  • Wind design: Region A, Terrain Category 2.
  • Roof: 75mm insulated roof panel, Surfmist external finish and 3° pitch.
  • Windows: white wet-area sliding windows with obscure/translucent glass, flyscreens and key locks.
  • External doors: 920mm commercial-grade steel entry doors.

Features included in your new toilet block

  • Separate male and female amenity areas.
  • Four wall-mounted stainless-steel basins with chrome basin mixers.
  • Wall-mounted 1200mm stainless-steel urinal trough with cistern.
  • White toilet suites and toilet partitioning with privacy indicators, door bumpers and coat hooks.
  • Framed vanity mirrors, hand-soap and paper-towel dispensers.
  • LED lighting, emergency exit signs, wall-mounted exhaust fans and hardwired smoke detectors.
  • Single-phase switchboard with RCD protection and external future-mains junction box.
  • Cold-water service to one male 20mm BSP connection point.

Important site requirements

Drains terminate below floor level at each fixture and at the perimeter wall; drain connection is not included. Transport, onsite installation/setup, footings and tie-downs are not included in the supplied project specification.

“,”_product_tab_content”:”field_6820ef62633e1″,”download_brochure”:92435,”_download_brochure”:”field_69de5f040d584″},”mode”:”edit”} /–>